Deflection limits: span/250

Keep beam deflection under span/250 generally, span/360 where people will notice a bouncy floor.

Why it works

Serviceability limits from building codes. A 4 m joist should sag no more than ~11 mm under load — stiffness governs long before strength does.

When it fails

A beam under a brittle plaster ceiling can crack at span/400, while a garden pergola at span/150 is perfectly serviceable. The limit is set by what the movement damages or who notices it, not by the beam — span/250 is a default for when nobody has told you which case you are in.

Do it exactly

Estimate with the rule, then check it against the calculator that models it properly.

Open Beam Deflection & Stress Calculator →

More in Mechanical

← PreviousTorque mostly fights friction Next →Depth beats width, cubed

How much deflection is acceptable in a beam?

Keep beam deflection under span/250 generally, span/360 where people will notice a bouncy floor. Serviceability limits from building codes.